Stress analysis of 12ft gate




  1. File Information
  2. Materials
  3. Load & Restraint Information
  4. Study Property
  5. Stress Results
  6. Deformation Results
  7. Design Check Results
  8. Appendix



1. File Information



Model name: 12ft gate
Model location: G:\Mark's Folder\Personal\12ft gate.SLDPRT
Results location: c:\temp
Study name: COSMOSXpressStudy




2. Materials



No. Part Name Material Mass Volume
1 12ft gate [SW]AISI 304 100.479 kg 0.0125599 m^3



3. Load & Restraint Information



Restraint
Restraint1 <> on immovable (no translation).
Description:


Load
Load1 <> on 2 Face(s) apply normal force 800 lb using uniform distribution
Description:

4. Study Property



Mesh Information
Mesh Type: Solid mesh
Mesher Used: Standard
Automatic Transition: Off
Smooth Surface: On
Jacobian Check: 4 Points
Element Size: 0.91529 in
Tolerance: 0.045765 in
Quality: High
Number of elements: 44275
Number of nodes: 88488



Solver Information
Quality: High
Solver Type: FFE



5. Stress Results



Name Type Min Location Max Location
Plot1 VON: von Mises stress
12.5001 N/m^2
(0 in,
48.6364 in,
-1 in)
7.22245e+008 N/m^2
(-123.545 in,
86 in,
0 in)



12ft gate-COSMOSXpressStudy-Stress-Plot1
JPEG
VIEW



6. Deformation Results



Plot No. Scale Factor
1 2.9183



12ft gate-COSMOSXpressStudy-Deformation-Plot2
JPEG
VIEW



7. Design Check Results



12ft gate-COSMOSXpressStudy-Design Check-Plot3
JPEG
VIEW



8. Appendix



Material name: [SW]AISI 304
Description:
Material Source: Used SolidWorks material
Material Library Name:
Material Model Type: Linear Elastic Isotropic
Unit system: SI

Property Name Value
Elastic modulus 1.9e+011 N/m^2
Poisson's ratio 0.29
Yield strength 2.0681e+008 N/m^2
Mass density 8000 kg/m^3







Note:

COSMOSXpress design analysis results are based on linear static analysis and the material is assumed isotropic. Linear static analysis assumes that: 1) the material behavior is linear complying with Hooke’s law, 2) induced displacements are adequately small to ignore changes in stiffness due to loading, and 3) loads are applied slowly in order to ignore dynamic effects.

Do not base your design decisions solely on the data presented in this report. Use this information in conjunction with experimental data and practical experience. Field testing is mandatory to validate your final design. COSMOSXpress helps you reduce your time-to-market by reducing but not eliminating field tests.